Friday, October 3, 2008

Test 000-062 for you to reference

High quality and Value for the 000-062 Exam.
Killtest Practice Exams for IBM System p5 Virtualization Technical Support 000-062 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.

100% Guarantee to Pass Your System Administator exam and get your System Administator Certification. We guarantee your success in the first attempt. If you do not pass the 000-062 exam (IBM System p5 Virtualization Technical Support) on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.

40. A customer has recently received a new p5-570 in the data center and intends to Micro-Partition the server. In which order should installation steps be taken?
A. Connect to the network, power on the server, Micro-Partition the server.
B. Connect to the HMC, power on the server, Micro -Partition the server, connect to the network.
C. Power on server, connect to the network, Micro -Partition the server, connect to the HMC.
D. Power on the server, connect to the HMC, Micro-Partition the server, connect to the network.
Answer: B

41. A customer has recently received a new p5-570 in the data center and wants to Micro-Partition the server. The customer already has an existing HMC connected to a p690. Which of the following actions should the technical specialist take?
A. Order a POWER5 HMC.
B. Connect to the existing HMC.
C. Install an 8-port asynchronous card in the managed server to connect to the existing HMC.
D. Install an additional network card to the existing HMC and connect t o the POWER5 service processor.
Answer: A

42. A customer has recently received a new p5-570 in the data center and wants to connect it to an existing HMC environment where each of the existing POWER5 servers has been assigned a static IP address. Which of the following actions should the technical specialist perform to set the service processor network addr ess for a static IP?
A. Configure the IP address through the first client partition.
B. Configure the IP address through the ASMI menus.
C. Configure the POWER5 service processor for DHCP from the HMC DHCP server.
D. Configure the HMC to use the default IP address on the service processor when acquiring the managed server.
Answer: B

43. A technical specialist defined a virtual Ethernet ent2 on the VIO server that has a physical adapter, ent0. Which of the following commands should be used to configure the Shared Ethernet Adapter?
A. mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1
B. mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1
C. mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
D. mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1
Answer: C

http://www.killtest.com/SystemAdministator/000-062.asp

No comments: